Łączniki wielopoł. (60°) bez położenia 0 TM-5-8252/E

  • szt.
  • Cena brutto: 717,09 zł 583,00 zł
Łączniki wielopoł. (60°) bez położenia 0 TM-5-8252/E
Program
Range
  Mini rotary switches
Basic function
  Step switches
Part group reference (e.g. DIL)
  TM
Design
  Flush mounting
 
  
Protection type
  Front IP65
Emergency stop
  without emergency switching off/emergency stop function
 
  Without 0 (Off) position
Number of steps
  5 steps, 60°
Contact sequence
  
Front plate no.
  
Main conducting paths
   
No. of poles
 M2
Max. motor rating
   
AC-23A
   
400/415 V

50-60 Hz

PkW3
Rated uninterrupted current
IuA10
Approbationen
Product StandardsUL 508; CSA-C22.2 No. 14-05; IEC/EN 60947-3; CE marking
UL File No.E36332
UL CCNNLRV
CSA File No.UL report applies to both US and Canada
CSA Class No.
NA CertificationUL Listed, certified by UL for use in Canada
 
General
Standards
  IEC/EN 60947, VDE 0660 UL, CSA
Control switches to IEC/EN 60947-5-1
Control circuit isolators to IEC/EN 60947-5-1
Control circuit isolators (IEC/EN 60947-5-1)
  Maximum 6 contacts; switching angle 90°
Lifespan, mechanical
Operationsx 106> 1
Maximum operating frequency
Operations/h 3000
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Ambient temperature
 °C 
Open
 °C-25- 50
Enclosed
 °C-25- 40
Mounting position
  As required
Terminal capacities
 mm2 
Solid
 mm21 x 1,5
2 x 1,5
Flexible without ferrule
 mm21 x 1,5
2 x 1,5
Solid or stranded
 AWG1 x 14
2 x 14
Flexible
 AWG1 x 16
2 x 16
Terminal screw
  M2.5
Tightening torque
 Nm0.35
Contacts
Mechanical variables
   
Contacts
 NumberMax. 16
Contact units
  8
Switching angles
 °90
60
45
30
Min. switching angle for On-Off-On
 °60
Max. number of switch positions
  12
Thickness of gold coating
 µm35
Electrical characteristics
   
Rated operational voltage
UeV AC500
Rated impulse withstand voltage
UimpV AC4000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC500
Rated insulation voltage for UL/CSA
 V AC300
Rated uninterrupted current
IuA10
Switching capacity
 kA 
AC-23 Motor load switches
   
230 V AC, 3-pole
 kW1.8
440 V AC, 3-pole
 kW3
230 V AC, 1-pole
 kW0.75
440 V AC, 1-pole
 kW1.1
AC-15 Control switches
   
230 V AC, 1-pole
 A2.5
400 V AC, 1-pole
 A1.5
440 V AC, 1-pole
 A1
DC-13, Control switches L/R = 50 ms
   
Rated operational current
IeA3
Voltage per contact pair in series
 V32
Switching capacity (UL489, CSA 22.2 No. 5.1)
   
240 V AC, 3-pole
 HP1
277 V AC, 1-pole
 HP¾
300 V AC Heavy duty
 A10
Max. short-circuit protective device
   
Fuse
 A gG/gL10
Control circuit reliability at 24 V DC, 10 mA
Fault probabilityHF< 10-5, < 1 fault in 100000 operations
Technical data according to ETIM 4.0
Suitable for front mounting
  YES
Complete device in housing
  No
Suitable for rear mounting
  No
Device construction
  Flush-mounting device
Type of control element
  Toggle
Max. rated operating voltage Ue at AC
 V500
Rated uninterrupted current Iu
 A10
Protection type (IP), at front
  IP65
Front shield size
  30x30 mm
Suitable for base fixing
  No
Switch function
  On/Off switch
Number of poles
  2
Number of switch positions
  5
Suitable for distribution board installation
  No
Dimensions
Depth of one contact unit: 12 mm
Diameter of drilled hole Door

Opis pochodzi ze strony www.moeller.net .